BRAND | Fluke |
Product | 5320A |
Description | Multifunction Electrical Tester Calibrator |
Internal code | IMP4537642 |
Technical specification | Precision Low Resistance Source Ranges: 100 mΩ to 10 kΩ Resolution: 3 ½ digits (continuously variable) Maximum Current Ranges: 5 mA to 400 mA Modes: 2-Wire and 4-Wire Best 1 Year Specification: ± 0.2 % of setting High Resistance Source (High voltage) Ranges: 10 kΩ to 100 GΩ Resolution: 4 ½ digits (continuously variable to 10 GΩ) Maximum Voltage Ranges: 55 Vpk to 1575 Vpk Best 1 Year Specification: ± 0.2 % of setting Resistance Multiplier Adapter¹ (for high resistance source) Resistance Ranges: 350 MΩ to 10 TΩ Maximum Test Voltage: 5500 V dc Best 1 Year Specification: Uncertainty of 5320A resistor to be multiplied ± 1 % of displayed value Low Resistance Source (High current) Ranges: 25 mΩ to 1.8 kΩ, 16 values Maximum Current Ranges: 0.025 A to 30 A (continuous) 0.15 A to 40 A (short-term) Best 1 Year Specification: ± 5 mΩ of setting Loop Compensation: 0 to 10 Ω (Scan Mode) 0 to 2 Ω (Active Comp Mode) Loop Compensation Specification: ± 1 % + 15 mΩ (Scan and active comp Mode) Active Loop Compensation available on 5320A/VLC only Line Leakage Current Source Ranges: 0.1 mA to 30 mA Resolution: 10 uA of setting Test Voltage Ranges: 10 to 250 V Modes: Passive, Differential, Substitute, Active Best 1 Year Specification: ± 0.3% + 1 uA of setting Residual Current Device Trip Current Ranges: 3 to 3000 mA Trip Current Modes: 0.5xI, 1xl, 1.4xI, 2xI, and 5xI Best 1 Year Trip Current Specification: ± 1 % rms Trip Time Ranges: 10 to 5000 ms Best 1 Year Trip Time Specification: ± 0.25 ms Multimeter Voltage Ranges: 0 to 1100 V ac rms or dc Voltage Resolution: 4 ½ digits Best 1 Year Voltage Specification: ± 0.15% of reading + 5 mV Current Ranges: 0 to 30 A ac rms or dc Current Resolution: 4 ½ digits Best 1 Year Current Specification: ± 0.15% of reading + 0.15 mA Phantom Power: 0 to 33 kVA Phantom Power Resolution: 3 digits Best 1 Year Power Specification: √((V)² + (I)²) Hipot Leakage Current Measurement Mode (Multimeter mode) Current Range 0 to 300 mA acrms or cc Current Resolution 4 ½ digits Best 1 Year Specification ± 0.2% of reading + 0.21 mA Hipot Timer Measurement Mode (Multimeter mode) Timer Measurement Range 0.1 to 999 s Timer Resolution 1 ms Best 1 Year Specification 0.02% + 2 ms (dc) 0.02% + 20 ms (ac) 10 kV Divider Adapter¹ (for multimeter input) Voltage Ranges: 0 to 10 kV ac peak or dc Voltage Divider Ratio: 1000:1 Best 1 Year Specification: ± 0.3 % of reading + 5 V dc ± 0.5 % of reading + 5 V ac (50 or 60 Hz) 40 kV Probe² (for multimeter input) Accessory Voltage Ranges: 0 to 40 kV ac peak or dc Voltage Divider Ratio: 1000:1 Best 1 Year Specification: ± 0.5 % of reading + 10 V dc ± 0.5 % of reading + 10 V ac (50 or 60 Hz) Voltage Calibrator Source (5320A/VLC only) Ranges: 3 to 600 V ac or dc Voltage Resolution: 4 digits Frequency: 40 to 400 Hz Frequency Resolution: 3 digits Maximum Burden Current: 500 mA (ac) 5 mA (dc) Best 1 Year Current Specification: ± 0.1 % of setting + 9 mV |
Press on flag images to see contact information!