Prices  5320A  Fluke  Bulgaria

BRAND Fluke
Product 5320A
Description Multifunction Electrical Tester Calibrator
Internal code IMP4537642
Technical specification Precision Low Resistance Source Ranges: 100 mΩ to 10 kΩ Resolution: 3 ½ digits (continuously variable) Maximum Current Ranges: 5 mA to 400 mA Modes: 2-Wire and 4-Wire Best 1 Year Specification: ± 0.2 % of setting High Resistance Source (High voltage) Ranges: 10 kΩ to 100 GΩ Resolution: 4 ½ digits (continuously variable to 10 GΩ) Maximum Voltage Ranges: 55 Vpk to 1575 Vpk Best 1 Year Specification: ± 0.2 % of setting Resistance Multiplier Adapter¹ (for high resistance source) Resistance Ranges: 350 MΩ to 10 TΩ Maximum Test Voltage: 5500 V dc Best 1 Year Specification: Uncertainty of 5320A resistor to be multiplied ± 1 % of displayed value Low Resistance Source (High current) Ranges: 25 mΩ to 1.8 kΩ, 16 values Maximum Current Ranges: 0.025 A to 30 A (continuous) 0.15 A to 40 A (short-term) Best 1 Year Specification: ± 5 mΩ of setting Loop Compensation: 0 to 10 Ω (Scan Mode) 0 to 2 Ω (Active Comp Mode) Loop Compensation Specification: ± 1 % + 15 mΩ (Scan and active comp Mode) Active Loop Compensation available on 5320A/VLC only Line Leakage Current Source Ranges: 0.1 mA to 30 mA Resolution: 10 uA of setting Test Voltage Ranges: 10 to 250 V Modes: Passive, Differential, Substitute, Active Best 1 Year Specification: ± 0.3% + 1 uA of setting Residual Current Device Trip Current Ranges: 3 to 3000 mA Trip Current Modes: 0.5xI, 1xl, 1.4xI, 2xI, and 5xI Best 1 Year Trip Current Specification: ± 1 % rms Trip Time Ranges: 10 to 5000 ms Best 1 Year Trip Time Specification: ± 0.25 ms Multimeter Voltage Ranges: 0 to 1100 V ac rms or dc Voltage Resolution: 4 ½ digits Best 1 Year Voltage Specification: ± 0.15% of reading + 5 mV Current Ranges: 0 to 30 A ac rms or dc Current Resolution: 4 ½ digits Best 1 Year Current Specification: ± 0.15% of reading + 0.15 mA Phantom Power: 0 to 33 kVA Phantom Power Resolution: 3 digits Best 1 Year Power Specification: √((V)² + (I)²) Hipot Leakage Current Measurement Mode (Multimeter mode) Current Range 0 to 300 mA acrms or cc Current Resolution 4 ½ digits Best 1 Year Specification ± 0.2% of reading + 0.21 mA Hipot Timer Measurement Mode (Multimeter mode) Timer Measurement Range 0.1 to 999 s Timer Resolution 1 ms Best 1 Year Specification 0.02% + 2 ms (dc) 0.02% + 20 ms (ac) 10 kV Divider Adapter¹ (for multimeter input) Voltage Ranges: 0 to 10 kV ac peak or dc Voltage Divider Ratio: 1000:1 Best 1 Year Specification: ± 0.3 % of reading + 5 V dc ± 0.5 % of reading + 5 V ac (50 or 60 Hz) 40 kV Probe² (for multimeter input) Accessory Voltage Ranges: 0 to 40 kV ac peak or dc Voltage Divider Ratio: 1000:1 Best 1 Year Specification: ± 0.5 % of reading + 10 V dc ± 0.5 % of reading + 10 V ac (50 or 60 Hz) Voltage Calibrator Source (5320A/VLC only) Ranges: 3 to 600 V ac or dc Voltage Resolution: 4 digits Frequency: 40 to 400 Hz Frequency Resolution: 3 digits Maximum Burden Current: 500 mA (ac) 5 mA (dc) Best 1 Year Current Specification: ± 0.1 % of setting + 9 mV

Fluke - 5320A referenced Multifunction Electrical Tester Calibrator product produced by high technology.
You can provide the all references you look for in endustrial accessories in our company with our unique product range. 5320A referenced product which is satisfy the customer's needs, offers advantages of quality and cost. You can find the most competitive prices about endustriel accessories in our company. Our established relationships with producers from all around the world and their official representatives helps us to meet your needs for spare parts, machinery, consumables and other products of the industrial field.

Sales Offices!

Press on flag images to see contact information!