INGREDIENTS
aqua pulse 1l; System module pulse Pulse value: 1 liter Pulse width: 50 ms Switching capacity: max. 220 mA, 48 V DC Cable length, fixed: 1.5 m Supply: 3 V lithium battery Battery life: 15 years Re-running detection with compensation Degree of protection: IP 68
System module aquapuls ®For Updating of aquabasic ® cold water meters.Pulse is 1 l / pulse with return compensation.Switching capacity 220 mA/48 VDC. IP 68with 1.5 m cable, securely mounted. With battery power
Modbus communication modul for alec ST
[M-Bus Mini-Master USB - M-Bus level converter Mobile M-Bus level converter with USB interface, - Integrated M-BUS power supply (32 M bus load units) - Two LED to indicate data traffic in sending and receive direction - Protection against overcurrent and short circuit on the M-Bus - supply from the USB interface, no external Supply needed]
VSR 32 1 1 / 4'' OR Klinger Sil; Fittings DN 32 Fittings R 1 1/4 " Union nuts G 1 1/2 " without boundary (brass) with seals
VSR 40 1 1/2 '' OR Klinger Sil; Fittings DN 40 Fittings R 1 1/2 " Union nuts G 2 " without boundary (brass) with seals
some glands
Ring piston Durchflussm. DOMINO rotary piston meters - stainless steel casing, flanges DIN 2501 - measuring chamber stainless steel - piston ring graphite - seals PTFE / Variseal
tellers
DOMINO® ARD Construction Group - Reguliergetriebe - pulser for high temperatures NAMUR / DIN 19234 - Roller 6 digits, rotatable. - lock ring with lid
Nominal flow: Qn = 6; Nominal diameter: DN 32; Reporting: 1 liter of 1impuls
Nominal flow: Qn = 10; Nominal diameter: DN 40; Reporting: 1 liter of 1impuls water meter
Nominal flow: Qn = 6; Nominal diameter: DN 32; Reporting: 1 liter of 1impuls
Nominal flow: Qn = 6; Nominal diameter: DN 32; Reporting: 1 liter of 1impuls
Nominal flow: Qn = 10; Nominal diameter: DN 40; Reporting: 1 liter of 1impuls
Nominal flow: Qn = 10; Nominal diameter: DN 40; Reporting: 1 liter of 1impuls
Nominal flow: Qn = 6; Nominal diameter: DN 32; Reporting: 1 liter of 1impuls
Nominal flow: Qn = 6; Nominal diameter: DN 32; Reporting: 1 liter of 1impuls
Nominal flow: Qn = 6; Nominal diameter: DN 32; Reporting: 1 liter of 1impuls
(CONTOIL ® fuel oil meters Reed pulser Pulse value 12.5 ml Nominal diameter: 8 mm With female thread for Kupferrohrverschr. 1/4 " Nominal pressure: PN 25 Maximum permissible temperature: 60 ° C Mounting position: horizontal / vertical Largest flow Qmax. 200 l / h In continuous operation: 135 l / h Error of measurement: 4-200 l / h ± 1% of measured value Pulse value: 0.0125 l)
VZO 15 ... 40 with thread, PN 16
oil meter Nominal width: DN 20 mm With flanges DN 20 according to: DIN 2501 Overall length: 165 mm Nominal pressure: PN 25 bar Maximum allowable temperature: 130 ° C Mounting position: horizontal / vertical Largest flow Qmax. 1,500 l / h In continuous operation Qn:. 1,000 l / h Minimum flow Qmin. 30 l / h Error of measurement: 30 - 1,500 l / h ± 1% of measured value Repeatability equal / better than: 0.2% Total amount on roller: 10 million liters Smallest readable Quantity: 0.1 l
oil meter
[AMBUS IS M-Bus pulse collector 1 pulse input 2 conductors M-bus interface 2 conductors with energy supply from AMBUS ZS or Net]
PMG 32-RH1 6.0_260_1 G1 / 4 multi-jet vane hot water meter in glanded Thread connection: G 1 1/2 " Nominal size: DN 32 Mounting length: 260 mm Mounting position: horizontal Temperature: max. 130 ° C Nominal pressure: PN 16 Minimum flow qi: 0,075 m³ / h Continuous flow qp: 6 m³ / h Maximum flow qs: 12 m³ / h Kvs-value: 12.7 m³ / h Pressure loss at qp: 0,22 bar Pulse value: 1 liter / pulse Environmental class C according to EN 1434 no inlet: 0 x DN 32 no outlet flow: 0 x DN 32 Approval MI-004
Size: DN 32 with thread 1 1/2 "(for screw 1 1/4") Nominal pressure: PN 16 bar length: 150 mm Mounting position: vertical falling temperature max .: 130 ° C Maximum flow qs: 6.3 m3 / h Nominal flow qp: 5 m3 / h minimum flow qi: 0.1 m3 / h pulse value: 1 l Smallest readable amount: 0.1 l registrable: 99,999 m3 measuring principle: multi-jet impeller, dry running With CE marking
PMGS 32-RH1 5.0_150_1 G1 / 4 multi-jet vane hot water meter in glanded Thread connection: G 1 1/2 " Nominal size: DN 32 Mounting length: 150 mm Mounting position: vertical ascending Riser counter Temperature: max. 130 ° C Nominal pressure: PN 16 Minimum flow qi: 0.1 m³ / h Continuous flow qp: 5 m³ / h Maximum flow qs: 6,3 m³ / h Kvs-value: 13.6 m³ / h Pressure loss at qp: 0,14 bar Pulse value: 1 liter / pulse Environmental class C according to EN 1434 no inlet: 0 x DN 32 no outlet flow: 0 x DN 32 Approval MI-004
MeiStream RUBIN cold water meters Nominal size: DN 50 Flange connection: EN 1092-1 Nominal pressure: PN 16 bar Overall length: 200 mm Mounting position: horizontal / vertical Protection: IP 68 Temperature max .: 50 ° C Overload flow Q4: 90 m3 / h Permanent flow rate Q3: 50 m3 / h Transition flow rate Q2: 0.4 m3 / h Minimum flow rate Q1: 0.15 m3 / h Smallest readable amount: 0.5 l Registration capacity: 1 million m3 Measuring principle: Woltman turbine Measuring range delivery designation: R 100