Prices  CFIB-4-RD-P3-ET-0-0  C.E. srl  Bulgaria

BRAND C.E. srl
Product CFIB-4-RD-P3-ET-0-0
Description Custody
Internal code IMP5015563
Custom code 903300
Technical specification GLOBTOP CF series case mod. CFIB in aluminum alloy (copper ≤ 0.1%), with open/closed position indicator for rotary valves: ATEX Certification (BVI 19 ATEX 0006): Ex II 2 GD — Ex db IIC T6/T5/T4 Ex tb IIIC IP66/67 T85/T100/T135°C (Tamb. from -25°C to +60/+80/+100°C) - Cable entry: No. 3 3/4" npt-f - Terminal block: 12 terminals plus ground connection - Degree of protection: IP66/67/67M (with shaft rotation test) - Surface treatment: chromation (compliant with MIL5541 Class 1A) + polyester coating (RAL7000) (maximum resistance to chemical and atmospheric agents) - Position indicator: three-dimensional dome in red-green color - shaft coupling: namur In each case, n. 4 (2CH+2AP) JETREED magnetic proximity sensors will be mounted with the following characteristics: - magnetic limit switch Mod. P3 passive type (without power supply) - Reed type contact: SPDT in Rhodium (hermetic with inert gas) - DC-AC switching current: 1Amp maximum with resistive load - DC-AC switching voltage: 240V maximum resistive load - switching power WATTS DC/AC: maximum 25 VA-W resistive load - sensitive distance: 4 mm. - recovery distance: 0.6 mm. - switching time: 3.6 milliseconds - release time: 4.2 milliseconds - working temperature: see T.amb. of enclosure certification - housing material: PPS with flammability grade “V0” - nr.3 connecting conductors GLOBTOP CF series housing mod. CFIB in aluminum alloy (copper ≤ 0.1%), with open/closed position indicator for rotary valves: - ATEX Certification (BVI 19 ATEX 0006): Ex II 2 GD — Ex db IIC T6/T5/T4 Ex tb IIIC IP66/67 T85/T100/T135°C C (Also From -25°C to + 60/80/100°C) - Cable entry: nr.3 of 3/4" npt-f - Terminal block: 12 terminals plus earth connection - Protection degree: IP66/67/67M (with shaft rotation test) - Surface treatment: chromate (according to MIL5541 class 1A) + polyester painting (RAL7000) (maximum resistance to chemical and atmospheric agents) - Position indicator: red-green three-dimensional dome - Shaft coupling: namur In each housing, 4 (2CL+2OP) JETREED magnetic proximity sensors with the following will be mounted features: - Passive magnetic limit switch Mod. P3 (without power supply) - Reed contact: Rhodium SPDT (hermetic with inert gas) - DC-AC switching current: 1 Amp maximum with resistive load - DC-AC switching voltage: 240V maximum resistive load - DC/AC switching power: maximum 25 VA-W with resistive load - Sensitive distance: 4 mm. - Reset distance: 0.6 mm. - Switching time: 3.6 milliseconds - Release time: 4.2 milliseconds - Working temperature: see T.amb. custody certification - Casing material: PPS with “V0” flammability degree - 3 connection wires

default.send_request_amp_Group2